Soens Weather Station

Feature Support
Sending no
Receiving yes
Config yes

Supported Brands

Brand Protocol
Soens Weather Station soens
TFA tfa
Conrad conrad_weather

Sender Arguments

None

Config

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
{
  "devices": {
    "weather": {
      "protocol": [ "tfa" ],
      "id": [{
        "id": 108,
        "channel": 3
      }],
      "temperature": 18.90,
      "humidity": 41.00,
      "battery": 1
     }
  },
  "gui": {
    "weather": {
      "name": "Weather Station",
      "group": [ "Outside" ],
      "media": [ "all" ]
    }
  }
}
Option Value
id 0 - 9
temperature -39.9 - 59.9
humidity 10 - 99
battery 0 - 1

Note

Conrad

This sensor does not support humidity measurements

Optional Settings

Device Settings

Setting Default Format Description
temperature-offset 0 number Correct temperature value
humidity-offset 0 number Correct humidity value

GUI Settings

Setting Default Format Description
temperature-decimals 2 number How many decimals the GUIs should display for temperature
humidity-decimals 2 number How many decimals the GUIs should display for humidity
show-temperature 1 1 or 0 Don’t display the temperature value
show-humidity 1 1 or 0 Don’t display the humidity value
show-battery 1 1 or 0 Don’t display the battery value

Protocol

The tfa protocol sends 86 pulses like

498 1992 498 1992 498 1992 498 1992 498 1992 498 4233 498 4233 498 1992 498 1992 498 2241 498 1992 498 1992 498 2241 498 2241 498 1992 498 1992 498 4233 498 2241 498 2241 498 1992 498 1992 498 4482 498 1992 498 4233 498 4233 498 2241 498 4482 498 1992 498 1992 498 4233 498 1992 498 1992 498 4233 498 4233 498 1992 498 1992 498 1992 498 2241 498 2241 498 1992 498 4233 498 2241 498 8466

The next step is to transform this output into groups of 2 pulses.

498 1992
498 1992
498 1992
498 1992
498 1992
498 4233
498 4233
498 1992
498 1992
498 2241
498 1992
498 1992
498 2241
498 2241
498 1992
498 1992
498 4233
498 2241
498 2241
498 1992
498 1992
498 4482
498 1992
498 4233
498 4233
498 2241
498 4482
498 1992
498 1992
498 4233
498 1992
498 1992
498 4233
498 4233
498 1992
498 1992
498 1992
498 2241
498 2241
498 1992
498 4233
498 2241
498 8466

If we now look at carefully at these groups you can distinguish two types of groups:

  1. 498 1992
  2. 498 4233

So the first group is defined by a low 2nd, the second group has a high 2nd pulse. So we take either of these two pulses to define a 0 or a 1. In this case we say a high 2nd pulse means a 1 and a low 2nd pulse means a 0. We then get the following output:

000001100000000010000101101001001100000010

Each (group) of numbers has a specific meaning:

  • ID: 2 till 9
  • Channel: 12 till 13
  • Temperature: 14 till 25
  • Humidity: 26 till 33
  • Battery: 34 till 35
ID : 00011000 | Channel : 00 | Temp : 011000010010 | Hum : 00111001 | Bat : 00
  • The ID is defined as a binary number
  • The Channel is defined as a binary number and specifies which channel the sensor uses
  • The Temperature is defined as a binary number and represents the temperature (value is given in fahrenheit strating at -90°F). Assuming that the Temp binary value is AAAABBBBCCCC, the formula to calculate the temperature value in °C is
(((DEC(CCCC)*256) + (DEC(BBBB)*16) + (DEC(AAAA))/10) - 90 - 32) * (5/9)
  • The Humidity is defined as a binary number. Assuming that the Hum binary value is AAAABBBB, the formula to calculate the humidity percentage is DEC(BBBB)*16 + DEC(AAAA)
  • The Battery identifies the state of the battery
ID : 24 | Channel : 1 | Temp : 18.56°C | Hum : 57% | Bat : OK

This protocol was created for pilight with the help of this thread: http://forum.pilight.org/Thread-New-Protocol-Wireless-Indoor-Outdoor-Weather-Station-with-3-Sensors

Comments

This weather station or just the sensor is available from several (mostly Chinese) suppliers on eBay or Alibaba. Description for device is usually like: “Digital Wireless Indoor/Outdoor Weather Station with 3 Remote Sensors”. The sensor can be identified by the option to choose from 3 different channels.

Humidity and battery are supported by this protocol. The battery function is not tested 100%. Please be aware that the ID of a sensor changes after you replace the batteries. Conrad sensor only provide temperature (no humidity).