Feature | Support |
Sending | |
Receiving | |
Config |
Supported Brands
Brand | Protocol |
LM75 | lm75 |
LM76 | lm76 |
Sender Arguments
None
Config
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 | {
"devices": {
"temperature": {
"protocol": [ "lm75" ],
"id": [{
"id": "0x49"
}],
"temperature": 17.2
}
},
"gui": {
"temperature": {
"name": "Temperature Sensor",
"group": [ "Misc" ],
"media": [ "all" ]
}
}
}
|
Option | Value |
id | valid i2c id |
temperature | -55 - 125 |
Changed in version 8.0.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 | {
"devices": {
"temperature": {
"protocol": [ "lm75" ],
"id": [{
"id": "0x49",
"i2c-path": "/dev/i2c-0"
}],
"temperature": 17.2
}
},
"gui": {
"temperature": {
"name": "Temperature Sensor",
"group": [ "Misc" ],
"media": [ "all" ]
}
}
}
|
Option | Value |
id | valid i2c id |
i2c-path | valid i2c path |
temperature | -55 - 125 |
Optional Settings
Device Settings
Setting | Default | Format | Description |
poll-interval | 5 | seconds | What should be the poll interval of the sensors |
temperature-offset | 0 | number | Correct temperature value |
GUI Settings
Note
LM75
Setting | Default | Format | Description |
temperature-decimals | 1 | number | How many decimals the GUIs should display for temperature |
show-temperature | 1 | 1 or 0 | Don’t display the temperature value |
Note
LM76
Setting | Default | Format | Description |
temperature-decimals | 3 | number | How many decimals the GUIs should display for temperature |